Air Handling Unit Ahu for HVAC Systems in Office Buildings

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Russian
to see all verified strength labels (14)
  • Air Handling Unit Ahu for HVAC Systems in Office Buildings
  • Air Handling Unit Ahu for HVAC Systems in Office Buildings
  • Air Handling Unit Ahu for HVAC Systems in Office Buildings
  • Air Handling Unit Ahu for HVAC Systems in Office Buildings
  • Air Handling Unit Ahu for HVAC Systems in Office Buildings
  • Air Handling Unit Ahu for HVAC Systems in Office Buildings
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • After Sales Service
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
Air handling unit
Operating Voltage
380/400 VAC
Noise Level
Ultra Quiet
Application Fields
Food Processing
Mounting
Ceiling Mount
Lifetime
15~20 years
Certification
CE
Weight (Kg)
100 Kg
Power(Kw)
0.25~4.4
Dimension(L*W*H)
1405*950*500mm
Warranty of Core Components
1 Year
Fan
1~2
Video Outgoing-Inspection
Provided
Core Components
Motor, Centrifugal Fans
Key Selling Points
Long Service Life
Applicable Industries
Other
Product Name
Air Handling Unit
Rated Air Volume(M³/H)
1500~15000
Machinery Test Report
Provided
Transport Package
Wooden Box
Specification
custom
Origin
Shandong, China
HS Code
8415909000
Production Capacity
1000

Product Description

Product Description
 
HVAC System Central AHU 200 TR Air Handling Unit for Indoor Farming with Cooling and Heating Capabilities
Air Handling Unit Ahu for HVAC Systems in Office Buildings
Air Handling Unit Ahu for HVAC Systems in Office Buildings
Air Handling Unit Ahu for HVAC Systems in Office Buildings
 
Air Handling Unit Ahu for HVAC Systems in Office Buildings
 
Product Parameters
 
Coils
Structure: Copper tube expertly integrated through hydrophilic aluminum fins
Copper Pipe Diameter: Precisely engineered at φ 12.88mm
Fin Thickness: Engineered to 0.15mm for optimal performance
Fin Spacing: Precisely set at 10 FPI for superior airflow
Number of Rows of Copper Tube: Robust 6-row configuration
Maximum Working Pressure: Designed to withstand up to 1.6M Pa = 16BAR (Tested at 2.5MPa)
Filtration
Dust Particle Filtration: Effective and reliable
Filter Material: High-efficiency non-woven fabric
Filter: Easily removable for hassle-free cleaning

AHU Cooling Capacity: (Evaluated under return air conditions)
AHU Heating Capacity: (Evaluated under return air conditions)
Model
Rated air flow
m3/h
External total pressure Pa
 
 
Fan
 
 
Noise dB(A)
 
 
4 Rows
6 Rows
8 Rows
Type
Power kW
Sets
 
KD(X)-1.5
1500
260
200
146
Direct connecting external rotor or belt drive centrifugal fan
0.32
1
55
KD(X)-2
2000
258
198
145
 
0.55
1
58
KD(X)-2.5
2500
256
200
146
 
0.55
1
58
KD(X)-3
3000
246
192
136
 
0.75
1
59
KD(X)-4
4000
256
198
146
 
0.55x2
2
60
KD(X)-5
5000
246
200
150
 
0.55x2
2
62
KD(X)-6
6000
246
192
138
 
0.55x2
2
62
KD(X)-7
7000
267
230
178
 
0.8x2
2
63
KD(X)-8
8000
355
305
252
 
0.8x2
2
63
KD(X)-10
10000
406
355
308
 
1.5x2
2
66
KD(X)-12
12000
460
400
346
 
1.8x2
2
69
KD(X)-13.5
13500
468
408
350
 
2.2x2
2
72
KD(X)-15
15000
510
446
395
 
3.0x2
2
73
 
Model
Rated air flow
m3/h
Cooling Capacity KW
 
 
Water Flow t/h
 
 
 
 
4 Rows
6 Rows
8 Rows
4 Rows
6 Rows
8 Rows
KD(X)-1.5
1500
8.4
10
11.3
1.60
2.11
2.62
KD(X)-2
2000
11.2
15.16
19.5
1.92
2.62
3.38
KD(X)-2.5
2500
13.9
18.96
24.6
2.39
3.26
4.25
KD(X)-3
3000
16.8
22.8
29.5
2.87
3.91
7.06
KD(X)-4
4000
22.1
30.23
39.39
3.8
5.2
7.76
KD(X)-5
5000
27.6
37.7
49.1
4.76
6.5
8.4
KD(X)-6
6000
33.26
45.33
60.9
5.73
7.81
8.76
KD(X)-7
7000
47.6
58.3
71.4
8.2
10
12.1
KD(X)-8
8000
49.6
66.4
82.6
8.6
10.3
13.2
KD(X)-10
10000
57.6
78.7
93.9
9.9
13.5
16.1
KD(X)-12
12000
69.6
88.1
112.5
12
15.1
19.3
KD(X)-13.5
13500
78.3
99.0
126.4
13.5
17.0
21.8
KD(X)-15
15000
87.0
110.0
140.5
15.0
18.9
24.2
 
Model
Rated air flow
m3/h
Heating Capacity KW
 
 
Water Flow t/h
 
 
 
 
4 Rows
6 Rows
8 Rows
4 Rows
6 Rows
8 Rows
KD(X)-1.5
1500
12.5
17.6
21.2
1.5
1.9
2.3
KD(X)-2
2000
17.8
22.8
29.5
1.9
2.3
2.9
KD(X)-2.5
2500
21.8
28.5
36.1
2.3
2.9
3.5
KD(X)-3
3000
26.1
34.2
44.2
2.9
3.5
4.2
KD(X)-4
4000
34.8
45.6
59
3.5
4.2
5.5
KD(X)-5
5000
43.6
57
73.7
4.2
5.4
6.7
KD(X)-6
6000
52.3
68.3
88.4
5.2
6.2
7.6
KD(X)-7
7000
66
79.4
103.2
6
7.3
11.9
KD(X)-8
8000
72
91.1
117
7.5
9.0
12.5
KD(X)-10
10000
87.1
113.9
149.4
8.7
9.8
12.7
KD(X)-12
12000
104.5
136.7
176
9.0
11.7
15.2
KD(X)-13.5
13500
117.6
153.8
199
11.8
13.2
19.6
KD(X)-15
15000
130.7
170.9
221
13
15.7
22
 
Model
L  mm
W  mm
H  mm
m*n
N
DNXX(in)
E
F
KD(X)-1.5
1105
700
500
320*200
 
DN32(5/4)
304
4Rows: F=99, 6Rows: F=165, 8Rows: F=231
KD(X)-2
1105
840
500
320*200
 
DN32(5/4)
304
 
KD(X)-2.5
1105
980
500
400*200
 
DN40(3/2)
304
 
KD(X)-3
1105
1120
500
400*250
 
DN40(3/2)
304
 
KD(X)-4
1105
1400
500
2-320*200
600
DN40(3/2)
304
 
KD(X)-5
1105
1680
500
2-400*200
700
DN40(3/2)
304
 
KD(X)-6
1105
1960
500
2-400*250
760
DN40(3/2)
304
 
KD(X)-7
1105
1960
580
2-400*250
760
DN40(3/2)
380
 
KD(X)-8
1105
1960
620
2-500*250
820
DN50(2)
418
 
KD(X)-10
1305
2080
680
2-500*320
820
DN50(2)
494
 
KD(X)-12
1305
2180
740
2-500*400
900
DN50(2)
570
 
KD(X)-13.5
1305
2280
780
2-500*400
900
DN50(2)
508
 
KD(X)-15
1305
2340
810
2-630*400
1000
DN50(2)
684
 
 
Air Handling Unit Ahu for HVAC Systems in Office Buildings
Air Handling Unit Ahu for HVAC Systems in Office Buildings
Air Handling Unit Ahu for HVAC Systems in Office Buildings
 
Air Handling Unit Ahu for HVAC Systems in Office Buildings
 
 
 
 
After Sales Service
 
Normal Process:
A. Delivery: Upon dispatch, we promptly send all relevant documents or tracking numbers to the customer. Continuous monitoring of logistics is ensured, and any updates are communicated immediately. Customers are notified to be prepared for receipt of the goods.

B. Receipt: Upon receipt, we contact the customer to confirm no damage occurred during transit. If damage is found, photographic evidence is obtained for verification. Compensation or replacement is offered as necessary. For minor, locally available parts, customers are advised on local purchase and replacement, with costs covered by us.

C. Installation: We provide comprehensive technical guidance, detailed drawings, or video support. If needed, our engineers can offer on-site installation services.

D. Use: Complimentary training on operation, daily maintenance, and safety precautions is provided to customers.

E. Warranty: We offer a machine warranty of 3-5 years and a control warranty of 1 year. Any damage within the warranty period is repaired free of charge. Post-warranty repair services are available for a reasonable fee.
Company Profile
 
For over 15 years, Dezhou Linghao Refrigeration Equipment Co., Ltd has excelled in the central air-conditioning industry. Our product range includes air source heat pumps, chillers, fan coils, air handling units, and rooftop packaged AC units, providing comprehensive one-stop procurement services. Our advanced R&D laboratories and professional team are equipped to meet your customized requirements. We look forward to collaborating for a mutually beneficial partnership.
 
Air Handling Unit Ahu for HVAC Systems in Office BuildingsAir Handling Unit Ahu for HVAC Systems in Office Buildings
 
 
FAQ
1, about the air handling unit

Air handling units are divided into vertical cabinet air conditioning units, horizontal cabinet air conditioning units, ceiling air conditioning units and combined air conditioning units.

2. About customization methods

You can contact us directly to customize according to your needs.

3. About the mode of transportation and delivery time

Start production after receiving the advance payment, and complete delivery after receiving the full payment. Usually by sea, or directly to your point of delivery.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now