Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit

Product Details
Customization: Available
After-sales Service: Video Technical Support
Warranty: 1 Year
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Russian
to see all verified strength labels (14)
  • Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
  • Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
  • Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
  • Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
  • Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
FP-51
Type
Fan Coil Unit
Air Tube Material
Galvanized Sheet
Corrosion Durability
Ultrahigh
Operating Voltage
230 VAC
Noise Level
Ultra Quiet
Application Fields
Carbon Steel, Stainless Steel, Fiberglass
Mounting
Ceiling Mount
Lifetime
15~20 years
Certification
CE, CCC
Condition
New
Weight (Kg)
22 Kg
Place of Origin
Shandong, China
Warranty of Core Components
1 Year
Install
Ceiling Type
Air Current
2380
Mechanical Inspection Report
Furnish
Core Component
Engine
Product Name
Box Fan Coil Unit
Cooling Capacity
1800~12600 Watts
Heating Capacity
2700~18900 Watts
Materials
Galvanized Steel
Norm
Custom
Transport Package
Wooden Box
Specification
custom
Origin
Shandong, China
HS Code
8415909000
Production Capacity
5000

Product Description

Product Description
Fan coil unit is mainly composed of centrifugal fan and coil heat exchanger. It is the terminal unit of the central air conditioning system. The fan sends indoor air or outdoor mixed air through the chiller for cooling or heating, and then sends the air into the room to reduce or increase the indoor temperature to meet people's comfort requirements.
Introducing the pinnacle of innovation in climate control - our Ceiling Air Conditioning Fan Coil Unit with Adjustable Airflow. This extraordinary unit stands as the ideal terminal product for central air conditioning systems, boasting a comprehensive assembly of a heat exchanger, strainer, fan, water pans, exhaust air valve, and sturdy support. Seamlessly blending the central heating or cooling air with your indoor environment, it ensures a consistent and comfortable room temperature, catering effortlessly to your cooling, heating, or humidification needs. Revel in a space that is invigoratingly fresh, serenely quiet, and enveloped in soothing warmth.
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Product Parameters
 
Features:• Our diverse range of products is meticulously designed to accommodate various installation methods and building structures.• The optimized tube configuration, paired with dual open sides featuring hydrophilic aluminum fins, significantly enhances the heat exchange rate.• A selection of multi-specification fans is available to satisfy varying air volume requirements.• Benefit from ultra-quiet operation, promoting a tranquil and comfortable living space.• Equipped with an LCD screen and remote controller, ensuring ease of operation and user convenience.• Experience a swifter heating rate compared to traditional radiators, with a more uniform distribution of airflow and temperature.
 
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning UnitHotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning UnitHotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning UnitHotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Packaging & Shipping
 
Our sophisticated logistics system ensures your product is shipped directly from our CN warehouse via JL (Economy), with a competitive shipping fee of $208.25 for a single unit. Expect your delivery by December 5, with robust protection measures in place including early delivery assurances or a 10% compensation for delays, secure payment methods, and an easy return and refund process for qualifying defective purchases.
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
 
 
 
Company Profile
 
Dezhou Linghao Refrigeration Equipment Co., Ltd. is a leading international commercial company in China, mainly designing and manufacturing centrifugal fans, axial fans, boiler induced draft fans and other ventilation equipment and parts. Fans, tanks and cooling towers can also be customized to suit your needs. Used in coal-fired power generation, metallurgy, paper making, cement and glass production, chemical industry, material treatment, sewage treatment, waste incineration, subway ventilation, industrial boilers and dust removal systems and other industrial systems.



Main products: centrifugal fan, axial fan, boiler induced draft fan, industrial fan and parts, water tank and cooling tower
Heat recovery ventilators, energy recovery ventilators, fresh air filtration systems, rotary heat exchangers (heat wheels and enthalpy wheels), air handling units, modular air cooling coolers (heat pumps), coolers and industrial air conditioners, etc.



Our principle is "customer-oriented, quality-centered". We have CE and ISO9001. On this basis, we strive to meet the needs of our customers in all aspects with high-quality products and services. As a result, our products are widely recognized in Egypt, Sudan, Saudi Arabia, Malaysia, Indonesia, Philippines, Japan, UAE, Mexico, Italy and other countries around the world.
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning UnitHotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning UnitHotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
 
 
 
 
 
 
 
 
 
Hotel HVAC Ventilation Box Fan Tray Butler Central Air Conditioning Unit
 
FAQ
 
Fault1: Water leakage
The drip tray overflowed. The common reasons are: the drainage outlet (pipe) is blocked, the water is not discharged or the drainage is not smooth.
1. The drip tray is tilted
2. The vent valve is not closed
3. The pipe joints are not tightly connected
4. The tuyere water leakage. Water leakage of tuyere can be used ABS material tuyere

Fault 2: The blowing wind is not cold enough (hot)
1. Improper setting of temperature gear;

2. There is air in the coil;

3. Abnormal water supply temperature;

4. Insufficient water supply;

5. Coil fin oxidation.