Fan coil unit
peculiarity
- Multiple models available: HP02~HP14
- E.S.P. : 12 Pa, 30Pa, 50Pa Optional
- Reliable and durable
- Efficient heat exchanger
- Low noise
- Flexible control
- Ultra-thin design to save more building space
- Easy to install and maintain
A variety of models are available
Fan coil units are available in standard (30pa) and high static pressure (50pa) versions to meet different needs and a wider range of applications.
The unit is compact, lightweight and beautiful, and its ultra-thin design can meet the requirements of the floor height and save more building space.
Reliable and durable
The main structure is molded by 1.0mm high-quality galvanized steel plate, the structure is stable, the surface is passivated, and it has certain anti-stripping ability.
Flexible control
Efficient control system, rapid response to temperature regulation, exquisite panels enhance the technical content of interior decoration.
Types of accessories
The unit has many kinds of accessories, split type design, economical installation and maintenance.
Usage scenario
Secure payments: Your transactions on are protected with state-of-the-art SSL encryption and PCI DSS data security protocols, ensuring every payment is safe and secure. Easy Return & Refund: Enjoy peace of mind with our hassle-free refund policy. If your order is incomplete or there are issues with the products, you are eligible for a refund. Additionally, take advantage of free local returns for defects on qualifying purchases, making your shopping experience worry-free and customer-friendly.
Our commitment to quality extends well beyond the point of sale with an impressive 24-month warranty on every heat pump and an 18-month warranty on every water tank, counting from the date of delivery. For our valued partners and distributors, or any long-term collaborations, we are pleased to offer extended and enhanced warranty terms, tailored and agreed upon through mutual discussion to ensure complete satisfaction and peace of mind.
Dezhou Linghao Refrigeration Equipment Co., Ltd. is a leading international commercial company in China, mainly designing and manufacturing centrifugal fans, axial fans, boiler induced draft fans and other ventilation equipment and parts. Fans, tanks and cooling towers can also be customized to suit your needs. Used in coal-fired power generation, metallurgy, paper making, cement and glass production, chemical industry, material treatment, sewage treatment, waste incineration, subway ventilation, industrial boilers and dust removal systems and other industrial systems.
Main products: centrifugal fan, axial fan, boiler induced draft fan, industrial fan and parts, water tank and cooling tower
Heat recovery ventilators, energy recovery ventilators, fresh air filtration systems, rotary heat exchangers (heat wheels and enthalpy wheels), air handling units, modular air cooling coolers (heat pumps), coolers and industrial air conditioners, etc.
Our principle is "customer-oriented, quality-centered". We have CE and ISO9001. On this basis, we strive to meet the needs of our customers in all aspects with high-quality products and services. As a result, our products are widely recognized in Egypt, Sudan, Saudi Arabia, Malaysia, Indonesia, Philippines, Japan, UAE, Mexico, Italy and other countries around the world.
Basic knowledge
1: What is an energy recovery ventilator?
Energy recovery ventilation (ERV) is an energy recovery process that exchanges energy in the air of a building or space that is normally depleted and uses it to treat (pre-treat) incoming outdoor ventilated air in residential and commercial HVAC systems.
During the warm season, the system is pre-cooled and dehumidified while humidifying and preheating during the cool season. The benefit of using energy recovery is the ability to meet ASHRAE ventilation and energy standards while improving indoor air quality and reducing the total capacity of HVAC equipment.
In summary, the Energy recovery ventilator (ERV) allows fresh air to enter the building while maintaining pre-regulated heating or cooling.
2: What is the working principle of the heat recovery fan?
The heat recovery fan consists of two fans for air supply and exhaust, an air filter, an energy recovery exchanger and an intelligent control system. Even if you close the Windows, the ventilator can provide fresh air to the room after multiple filters and expel polluted air from the room. Two fans allow for airflow and balanced ventilation. At the same time, standard heat exchangers can recover the energy of the exhaust gas and return the incoming fresh air. Therefore, it is able to cool the outdoor air in the summer and warm the outdoor air in the winter, and the power consumption is low.
3: What is the difference between heat recovery and energy recovery?
Heat recovery heat exchangers transfer heat from one air stream to another and do not allow water transfer. This means they are well suited to climates where summer humidity levels are quite low.
The energy recovery exchanger provides heat and moisture recovery, allowing moisture to be transferred from the incoming air stream to the outgoing exhaust stream in humid summer conditions, thereby providing dehumidification, thereby increasing occupant comfort and reducing the risk of mold. They are ideal for locations with high humidity.
4: How to choose AHU?
AHU is designed and selected according to professional software to provide users with reasonable, economical and practical air conditioning solutions. AHU Selection software features also include:
Sound project and AHU inquiry management
Accurate airflow and element section division
Multiple heat recovery options and functional cross section combinations
Main section
Various optional components are calculated for air status points
Flexible unit combination
Professional and detailed selection report output
5: Does the heat recovery fan consume a lot of electricity?
Compared with air conditioning, heat recovery fans are more energy efficient. Even though it works 24 hours a day in pursuit of fresh air, it is also very environmentally friendly. For example, the 350m³/h energy recovery ventilator is suitable for a 150 m2 house. This product is equipped with DC motor. The low and high speed input power of this model ranges from 16w to 120w, while the power consumption ranges from 0.38KW/ day to 2.88KW/ day. If the electricity price is $0.1 / KWH, it only costs $0.38 to $0.288 per day
. To sum up, the energy recovery fan is energy saving.